Wall outlet |
1 complaint: the plug that plugs into the wall socket and easily shake itself apart so that the flow of electricity labile (in conditions between connected and not connected).
Cause: finger clamp plate that functions contained in the plug socket in tenuous circumstances exceed the diameter of the plug finger.
How to fix: turn off the MCB switch, start opening the socket screws, pins (use alligator forceps / pliers taper) of each plate which serves to clamp the plug diameter smaller fingers, try plate hole diameter is not too small because if too small will be difficult finger plug coming, for sure try insert the plug into an outlet hole. z
2 Complaints: black colored receptacle and melt like burnt.
Cause: The result of the looseness of the plug (point 1) which entered into an outlet so that no contact occurs Causes heat in the area.
How to fix: if the socket is still feasible to use it to fix the same way as points 1, attach a grounding cable / grounding outlet to neutralize sparks.
3 Complaints: outlet can not supply power to the plug.
Cause: The cable outlet regardless of terminal or there is a path breaking wires of the main cable outlet to the electrical installation.
How to fix: start improving the way in points 1, then check and connect the cable that should be connected to the existing terminal in the socket, check and connect the electrical path from the outlet to the main line of electrical installations in the home.
How to install the grounding cable / grounding outlet
At the back of the socket there exist three terminals consisting of:
1. two terminals (a screw to secure the cable) connected to the clamp plate that serves Yag finger into a hole plug socket. Each terminal must be connected to the positive cable / pasa (alkaline black) and negative wires / neutral (usually blue) main line electrical installations.
2 One terminal is located in the middle between the terminals connected to the positive cable / cable pasa and negative / neutral, this terminal will be connected to the cable gruonding / grounding is generally yellow. When traced, the terminal will be associated with two small plates located in front of both the left and right outlet, the second plate serves to hold the plug so as not to be separated from the second outlet besides this plate later on the same plate in contact with the contained in the plug / jack. Use of grounding / grounding outlet is highly recommended to neutralize the existing power electronic devices in the body, especially the power / watt large as refrigerators, computers, and washing machines.