For those of you who just have an electric water pump machine and want to install or install an automatic switch or you who want to learn to install an electric water pump automatically switches to please listen to the following article, may be useful.

Installation of an automatic switch is necessary for an electric water pump so we do not bother to turn on the pump when the water in the reservoir is empty, or turn off the water in the pump saaat shelter is full. There are two types of auto switch mounted on the installation wiring for electric water pump automatically switches are:

Sakelar pompa bertekanan
Picture switch automatically pompa1

1 switch is mounted on the machine body, which is a type of switch that uses a water pressure system, the switch will supply power to the pumps when the pressure in the discharge pipe of small (open water tap) and the switch will cut off the electricity to the pumps when the pressure in the pipe spending huge pressure water (tap water enclosed), in other words, the machine will turn on the pump to drain the water when the tap is open and the engine is turned off when the tap is closed.
 
gambar sakelar otomatis tangki air
Pump automatically switches air2
  2 automatic switch mounted on the water tank / water tank / toren / water tank, this type of switch is mounted on the top of the reservoir water, when the water in the reservoir runs out then the switch will supply power to the water pump to drain the water into the water reservoir , and when the water in the reservoir is full, the switch will automatically shut off the engine pump. how the switch is supported by two pieces of rope tied to a float switch lever otomatios, when the water in the tank is empty, the second buoy will be exposed to the force of gravity that would pull the lever switch to "ON" and will turn on the pump to drain the water to the water reservoir water, when the water in the reservoir is full then the second will float up to the surface resulting in an automatic switch back to position: OFF ", then cut off the flow of electricity to the pump so that the water pump died and it stops the flow of water into the reservoir.
Whatever models automatically switch to your electric water pump, installation of the installation is the same way that disconnects the positive cable / phase / fire from the main line to the electrical installation of the electric water pump engine. for installation methods are as follows:

Click image to enlarge!
sakelar otomatis tangki airThe circuit automatically switches the water pump

Connect the positive cable to the main line of electrical installations in the home to one of the existing cable terminal on the switch automatically.
     Connect the cable terminal automatically switch to the other one wired electric water pump engine.
     Connect the negative cable from the main line of electrical installations in the home to the cable machine is not connected to the pump everywhere.
     Wrap each cable connection is open or shorted to prevent our skin touched.
     If necessary attach a grounding cable to the body of the pump machine by connecting the grounding cable to one of the screws that attach the bodywork.

For automatic switch mounted on the machine body pump system that uses the water pressure after installing the first switch wiring must be carried out before the pump is used to adjust the suits "per / spring" that exist in the way the switch is:

     close all taps and open one of the taps.
     if the engine does not turn rotate the pump until the engine starts baud setter and let stand for bebeerapa moment.
     when the machine turns on with a steady flow of water and then close the tap that had been re-opened and wait for a while.
     if the engine does not stop just turn the adjusting baud reverse direction to the direction of the previous round until the engine stops pump on / off.

Automatic switch will work normally for water at the source (bore wells / dug wells) and surface water still clinging to the pipe and the condition of the switch in top shape. When the source of water in the empty and no water is flowing into the engine while the engine pump for long life engine heat pump will cause the pump motor winding broke up because burning, to keep such a thing should not happen on a cable attached from the path the main power switch is automatically installed into a manual switch is placed in an easily accessible place, so when we would leave the house in a relatively long period of time with feelings of safety then simply press the manual switch to "OFF".